One Controller for Grid-Compliant Plant Output.
The Intellisolar Power Plant Controller (PPC) sits between the grid operator and your inverters, measuring at the Point of Interconnection (POI) and coordinating every inverter so the whole plant behaves as a single, grid-code-compliant generator.
INTELLISOLAR PPC
Active Power at POI
Reactive Power Setpoint Met
Operator Curtailment Setpoint
Within Grid Code Band
Plant-Level Closed-Loop Control.
The PPC closes the loop between grid operator commands, POI measurements and inverter setpoints, so the plant follows dispatch and grid-code requirements automatically.
SLDC / GRID OPERATOR
Active power limits, power factor and reactive power setpoints arrive from the grid operator over SCADA.
POWER PLANT CONTROLLER
Compares POI measurements with the targets and calculates the setpoint for every inverter.
INVERTER FLEET
All online inverters follow their share of the plant setpoint, so the plant responds as one unit.
POINT OF INTERCONNECTION
POI meters feed active power, reactive power, voltage and frequency back to the controller.
SLDC / GRID OPERATOR
COMMAND RECEIVEDActive power limits, power factor and reactive power setpoints arrive from the grid operator over SCADA.
POWER PLANT CONTROLLER
P • Q(V) • RAMP ACTIVECompares POI measurements with the targets and calculates the setpoint for every inverter.
INVERTER FLEET
SETPOINT SHAREDAll online inverters follow their share of the plant setpoint, so the plant responds as one unit.
POINT OF INTERCONNECTION
PF 0.99 • 50.01 HzPOI meters feed active power, reactive power, voltage and frequency back to the controller.
Know What's Happening At Your Point of Interconnection.
Five continuous capabilities that keep your plant within its interconnection agreement while following operator dispatch.
Active Power Control
CURTAILMENT & RAMP-RATE LIMITING
Reactive Power & Voltage
POWER FACTOR, Q SETPOINT & Q(V) CONTROL
Frequency Response
P(f) DROOP & FREQUENCY SUPPORT
Inverter & Storage Coordination
MULTI-VENDOR FLEET CONTROL
Compliance & Reporting
SETPOINT TRACKING & AUDIT LOGS
Active Power Control
CURTAILMENT & RAMP-RATE LIMITING
Limit plant output to the commanded setpoint and control how fast it changes.
Plant Control & Grid Compliance, in One View.
Monitor POI active and reactive power, grid frequency, SLDC setpoints, controller modes and inverter dispatch in real time from one supervisory interface.
Grid Compliance Without Manual Intervention.
Keep your plant compliant with the grid code and the utility's dispatch instructions while getting the most from your generation.
FOLLOW GRID DISPATCH
Act on curtailment and setpoint commands automatically and confirm the plant has responded.
STAY WITHIN GRID CODE
Hold power factor, voltage support, ramp rates and frequency response within interconnection limits.
ONE PLANT, MANY INVERTERS
Coordinate multi-vendor inverters and storage so the plant responds as a single generator.
COMPLETE AUDIT TRAIL
Keep a timestamped record of every command and response for utilities, regulators and commissioning.
FOLLOW GRID OPERATOR DISPATCH
Act on curtailment and setpoint commands automatically and confirm the plant has responded.
STAY WITHIN GRID CODE
Hold power factor, voltage support, ramp rates and frequency response within interconnection limits.
ONE PLANT, MANY INVERTERS
Coordinate multi-vendor inverters and storage so the plant responds as a single generator.
COMPLETE COMPLIANCE RECORD
Keep a timestamped record of every command and response for utilities, regulators and commissioning.
Make Your Plant Behave Like One Grid-Compliant Generator.
Talk to Intellisolar about adding a Power Plant Controller to your utility-scale solar or hybrid project.